English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 46833/50693 (92%)
造訪人次 : 11866971      線上人數 : 671
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋
    主頁登入上傳說明關於CCUR管理 到手機版


    請使用永久網址來引用或連結此文件: https://irlib.pccu.edu.tw/handle/987654321/41170


    題名: 不同人體肢段參數之重心動態性誤差研究
    The Study of Dynamical Movement of the Human Center of Mass Measurement Errors by Different Body Segment Parameters
    作者: 黃長福
    陳重佑
    陳帝佑
    劉宇
    李志明
    貢獻者: 國術系
    關鍵詞: 生物力學
    人體測量學
    重心
    誤差
    Sports biomechanics
    Errors
    Anthropometry
    Center of mass
    日期: 2000-03
    上傳時間: 2018-11-21 13:16:23 (UTC+8)
    摘要: The purpose of this study is to use the displacement, velocity, and acceleration of body center of mass when performing the standing vertical jump from the force plate as a criterion to compare the errors of videotape when using different body segment parameters. Eighteen healthy male academics were served as the subjects for this study. A Kistler force plate (600Hz) and a Peak Performance high speed camera (120Hz) were synchro-nized to collect the subject performing the standing vertical jump. The vertical ground reaction forces and subject mass were used to calculate kinematical variables for the body center of mass during the vertical jumping. It was used as a criterion to compare the results of the body center of mss calculated from the videotape by using different methods of body segment parameters. Those methods including Dempster, Clauser, Zatziorsky & Seluyanov, Hu, Hanavan, Matsui, and Wang studies. The results showed the average standard error of estimate for displacement, velocity, and acceleration during action phase were 0.029 ± 0.009m, 0.164 ± 0.040m/s, 2.369 ± 0.527m/s2 respectively. During the flight phase, the average standard error of estimate for displacement, velocity, and acceleration were 0.041 ± 0.016m, 0.187 ± 0.061m/s, 0.897 ± 0.263m/s2 respectively. This study also indicated the error of kinematical variables in the body center of mass by Zatziorsky & Seluyanov, Hu, and Hanavan model were lower significantly than the other body segment parameters.The purpose of this study is to use the displacement, velocity, and acceleration of body center of mass when performing the standing vertical jump from the force plate as a criterion to compare the errors of videotape when using different body segment parameters. Eighteen healthy male academics were served as the subjects for this study. A Kistler force plate (600Hz) and a Peak Performance high speed camera (120Hz) were synchro-nized to collect the subject performing the standing vertical jump. The vertical ground reaction forces and subject mass were used to calculate kinematical variables for the body center of mass during the vertical jumping. It was used as a criterion to compare the results of the body center of mss calculated from the videotape by using different methods of body segment parameters. Those methods including Dempster, Clauser, Zatziorsky & Seluyanov, Hu, Hanavan, Matsui, and Wang studies. The results showed the average standard error of estimate for displacement, velocity, and acceleration during action phase were 0.029 ± 0.009m, 0.164 ± 0.040m/s, 2.369 ± 0.527m/s2 respectively. During the flight phase, the average standard error of estimate for displacement, velocity, and acceleration were 0.041 ± 0.016m, 0.187 ± 0.061m/s, 0.897 ± 0.263m/s2 respectively. This study also indicated the error of kinematical variables in the body center of mass by Zatziorsky & Seluyanov, Hu, and Hanavan model were lower significantly than the other body segment parameters.
    關聯: 體育學報 28 民89.03 頁305-314
    顯示於類別:[技擊運動暨國術學系] 期刊論文

    文件中的檔案:

    檔案 描述 大小格式瀏覽次數
    index.html0KbHTML140檢視/開啟


    在CCUR中所有的資料項目都受到原著作權保護.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋