文化大學機構典藏 CCUR:Item 987654321/35906
English  |  正體中文  |  简体中文  |  全文笔数/总笔数 : 46833/50693 (92%)
造访人次 : 11847924      在线人数 : 486
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜寻范围 查询小技巧:
  • 您可在西文检索词汇前后加上"双引号",以获取较精准的检索结果
  • 若欲以作者姓名搜寻,建议至进阶搜寻限定作者字段,可获得较完整数据
  • 进阶搜寻
    主页登入上传说明关于CCUR管理 到手机版


    jsp.display-item.identifier=請使用永久網址來引用或連結此文件: https://irlib.pccu.edu.tw/handle/987654321/35906


    题名: Experimental analysis of time-phase-shift flow sensing based on a piezoelectric peristaltic micropump
    作者: Huang, PC (Huang, Pao-Cheng)
    Wang, MH (Wang, Min-Haw)
    Chen, MK (Chen, Ming-Kun)
    Jang, LS (Jang, Ling-Sheng)
    贡献者: 電機系
    关键词: flow rate;;
    piezoelectric
    peristaltic micropump
    time-phase-shift (TPS)
    sensorless
    日期: 2016-05
    上传时间: 2017-04-13 15:31:25 (UTC+8)
    摘要: Flow rate sensing is a critical issue for piezoelectric-based micropump systems. This paper describes experimental analysis of flow rate sensing in a peristaltic micropump system. Sensing can be integrated with such a pump using piezoelectric actuators based on the time-phase-shift (TPS) method. To do this, an evaluation-window is added on the falling edge of the driving pulse to help detect the flow velocity without affecting the flow rate. We fabricate a prototype piezoelectric peristaltic micropump with three chambers and three piezoelectric actuators. The middle actuator works not only as an actuator for driving fluid but also as a transducer for sensing flow rate. An evaluation-window is performed to ascertain the relationship between the flow rate and the phase shift of output-signal responses from the transducer. The experimental results show that the evaluation-window response of flow rates in a piezoelectric peristaltic micropump has rates of from 5.56. 33.36 mu l s(-1). The results are extended to propose a practical flow rate sensor, the design of which can be realized easily in the piezoelectric peristaltic micropump system for sensorless responses that can detect flow rate without any sensors or circuits. The proposed TPS method is real-time, integrated, fast, efficient, and suitable for flow rate detection in piezoelectric peristaltic micropumps.
    關聯: JOURNAL OF PHYSICS D-APPLIED PHYSICS 卷: 49 期: 17 文獻號碼: 175402
    显示于类别:[電機工程系] 期刊論文

    文件中的档案:

    档案 描述 大小格式浏览次数
    index.html0KbHTML258检视/开启


    在CCUR中所有的数据项都受到原著作权保护.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回馈